Erection of a temporary load distribution frame for parts of a crane to be assembled during refurbishment activities at the reactor building crane

Customer:

NKM Noell Special Cranes GmbH

Service:

Structural calculation, frequency analysis and iterative optimisation of the load distribution frame to be designed for earthquake loading acc. to DIN 15018, KTA 2201 und DIN EN 1993