Calculation of 70 pipeline systems (200 isometric views) (operating temperature of 50 – 350°C, pressure 0 – 4 bar)
Customer:
Bühler AG, Schweiz
Service:
Calculation of pressure, weight and temperature loads. Check of pipe stress acc. to ASME B31.3 as well as the loads at the nozzle. Determination of the required pipe supports and variable spring hangers