New development of a water tank in Hückelhoven (diameter 4,25 m, height 9,4 m)
Customer:
Steinecker GmbH
Service:
Structural calculation of the watertank under wind, snow, and seismic loads as well as lifting acc. to AD2000 Merkblätter and DIN EN 1993-1 as well as analysis of buckling acc. to DIN EN 1993-1-6
„We need qualified personnel to manage the complex tasks in the future infrastructure planning.“
CEO Frank Mantel