Nukleartechnik – Rückbau KKW Stade

Dismantling of Power Plant Stade

Backfitting of openings without reinforcement in the containment of the reactor building

  • MAX STREICHER GmbH & Co. KG
Evaluation of the quality class on basis of the fabrication tolerance as well as structural proof (shell buckling) of the containment spherical shell (diameter 48 m, R/t=960) acc. to DIN EN 1993