Sprache auswählen:

Sprache auswählen:

Plant Engineering – Pipeline Construction

Satisfied customers are our best recommendation! Here you will find a selection of our projects, which reflect the comprehensive range of services of MF Engineering.

Rohrleitungsbau – Brauerei in Toronto, Kanada

Calculation of a pipe for a Millstar 10 t pump (operation temperature 85°C, pressure 10 bar)

Auftraggeber: GEA Brewery Systems GmbH
Leistung: Structural calculation and proof of the pipe under pressure, self-weight, temperature and seismic load acc. to ASME B31.3
Rohrleitungsbau – Brauerei in Lublin, Polen

Calculation of a support structure with pipe lines for draff and malt (operating temperature of 75°C, pressure 2 bar, dynamic

Auftraggeber: GEA Brewery Systems GmbH
Leistung: Structural calculation and proof of the pipes and supports under pressure, dead load and temperature as well as wind and snow acc. to EN 1991-1 (NA)
Rohrleitungsbau – Anlage in Lincoln, USA

Calculation of an anti-icing system (operation temperature -20 to 500°C, pressure 25 bar)

Auftraggeber: TB Freyer GmbH / Siemens Energy, Inc.
Leistung: Structural calculation and proof of the pipe and flanges under pressure, self-weight, temperature, wind, snow and seismic load acc. to ASME B31.1
Rohrleitungsbau – PET Anlage Brasilien

Calculation of 70 pipeline systems (200 isometric views) (operating temperature of 50 - 350°C, pressure 0 - 4 bar)

Auftraggeber: Bühler AG, Schweiz
Leistung: Calculation of pressure, weight and temperature loads. Check of pipe stress acc. to ASME B31.3 as well as the loads at the nozzle. Determination of the required pipe supports and variable spring hangers
Rohrleitungsbau – Rohrleitungsstücke

Calculation of single pipeline components

Auftraggeber: Krones AG
Leistung: Structural calculation and proof of the pipeline components under pressure and temperature loads acc. to ASME B31.3
Rohrleitungsbau – Brauerei in Chilliwack, Kanada

Calculation of a pipe for wort aeration (operation temperature 150°C, pressure 7 bar)

Auftraggeber: GEA Brewery Systems GmbH
Leistung: Structural calculation and proof of the pipe under pressure, self-weight, temperature, wind and seismic load acc. to ASME B31.3
Rohrleitungsbau – Brauerei in Chadyschensk, Russland

Calculation of steam and condensate pipe lines (operating temperature of 184°C, pressure 8 bar)

Auftraggeber: GEA Brewery Systems GmbH
Leistung: Structural calculation and proof of the pipes under pressure, dead load and temperature as well as wind snow and earthquake acc. to EN 13480 Part 3 - 2017, RU SP 20.13330 and UBC 1997

Calculation of a steam and a condensate pipe line (operating temperature of 180°C, pressure 10 bar)

Auftraggeber: GEA Brewery Systems GmbH
Leistung: Structural calculation and proof of the pipe under pressure, dead load and temperature as well as earthquake acc. to ASME B31.3 und NBCC 2010
Rohrleitungsbau – Entlüftungslaterne in Montreal, Kanada

Calculation of a daeration lantern integrated in a pipe system

Auftraggeber: GEA Brewery Systems GmbH
Leistung: Structural calculation and proof of the daeration lantern under pressure, weight and temperature loads as well as earthquake acc. to ASME B31.3
Rohrleitungsbau – Produktfalle in Montreal, Kanada

Calculation of a product trap integrated in a pipe system

Auftraggeber: GEA Brewery Systems GmbH
Leistung: Structural calculation and proof of the product trap under pressure, weight and temperature loads as well as earthquake acc. to ASME B31.3

New development and erection of dryer DN800 and purifier DN700 in Golden, Colorado, USA

Auftraggeber: GEA Brewery Systems GmbH
Leistung: Structural calculation and proof of the pipes acc. to ASME B31.3 under earthquake load acc. to ASCE 7-22
Rohrleitungsbau – CO2 Kompressor Einheit in USA

Calculation of pipe lines of a compressor unit incl. two cyclone separators in Glendale, Arizona, USA

Auftraggeber: GEA Brewery Systems GmbH
Leistung: Structural calculation and proof of the pipes and cyclone separators under pressure, dead load and temperature as well as earthquake acc. to ASME B31.3
Rohrleitungsbau – Feuerlöschleitung im KKW Grohnde

Calculation of a fire main incl. support under loading of airplane crash and under maintenance

Auftraggeber: PreussenElektra GmbH
Leistung: Structural calculation and design of the support acc. to DIN EN 1993 and of the pipe acc. to DIN EN 13480 based on response spectra for the building
Rohrleitungsbau – Anlage in Tadcaster, UK

Calculation of a steam pipe with condensate return (operation temperature 180°C, pressure 10 bar)

Auftraggeber: GEA Brewery Systems GmbH
Leistung: Structural calculation and proof of the pipe under pressure, self-weight and temperature load acc. to DIN EN 13480
Rohrleitungsbau – Anlage in Lincoln, USA

Calculation of heat exchange supply and drain piping (operation temperature -10 to 90°C, pressure 12 bar)

Auftraggeber: TB Freyer GmbH / Siemens Energy, Inc.
Leistung: Structural calculation and proof of the pipe and flanges under pressure, self-weight, temperature, wind, snow and seismic load acc. to ASME B31.1